Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 5.751
Filtrar
2.
Artigo em Inglês | MEDLINE | ID: mdl-38561572

RESUMO

BACKGROUND: Permanent pacing is often required following valve intervention (either surgical or percutaneous); however, tricuspid interventions pose specific challenges to conventional pacing. Therefore, leadless pacemaker (LP) implantation may be the preferred strategy when permanent pacing is required after tricuspid valve intervention. PURPOSE: To report periprocedural outcomes and follow-up of patients undergoing implantation of a LP system following tricuspid valve interventions. METHODS: Patients with previous tricuspid valve intervention at the time of attempted implantation of a LP (MicraTM, Medtronic, Minneapolis, MN, USA) were included. RESULTS: Between 2019 and 2022, 40 patients underwent LP implantations following tricuspid interventions in 5 large tertiary centers. The mean age was 68.9 ± 13.7 years, and 48% patients were male. The indication for pacing was as following: AVB in 27 (68%) patients, AF with slow ventricular response in 10 (25%) patients, and refractory rapid atrial fibrillation (AF) referred to AV junction ablation in 3 (7%) patients. Most of the patients received Micra VR (78%). The procedure was successful in all patients. The mean procedural time is 58 ± 32 min, and the median fluoroscopy time is 7.5 min. Electrical parameters were within normal range (threshold: 1.35 ± 1.2 V@0.24 ms, impedance: 772 ± 245 Ohm, R-wave: 6.9 ± 5.4 mV). No acute complications were observed. During a mean follow-up of 10 months, electrical parameters remained stable, and 4 deaths were occurred (not related to the procedure). CONCLUSION: A LP is a safe and efficient option following tricuspid valve interventions.

3.
Heart Rhythm ; 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38574789

RESUMO

BACKGROUND: Leadless pacemakers have emerged as a promising alternative to transvenous pacemakers in patients with kidney disease. However, studies investigating leadless pacemaker outcomes and complications based on kidney dysfunction are limited. OBJECTIVE: To evaluate the association of chronic kidney disease (CKD) and end-stage renal disease (ESRD) with inpatient complications and outcomes of leadless pacemaker implantations. METHODS: National Inpatient Sample and International Classification of Diseases, Tenth Revision codes were used to identify CKD and ESRD patients who underwent leadless pacemaker implantations in the U.S. from 2016-2020. Study endpoints assessed included inpatient complications, outcomes and resource utilization of leadless pacemaker implantations. RESULTS: A total of 29,005 leadless pacemaker placements were identified. Patients with CKD (n=5,245, 18.1%) and ESRD (n=3,790, 13.1%) were younger and had higher prevalence of important comorbidities than patients without CKD. In crude analysis, ESRD was associated with higher prevalence of major complications, peripheral vascular complications, and inpatient mortality. After multivariable adjustment, CKD and ESRD were associated with inpatient mortality (aOR 1.62, 95% CI 1.40 - 1.86; aOR 1.38, 95% CI 1.18 - 1.63) and prolonged length of stay (aOR 1.55, 95% CI 1.46 - 1.66; aOR 1.81, 95% CI 1.67 - 1.96). ESRD was also associated with higher hospitalization costs (aOR 1.63, 95% CI 1.50 - 1.77) and major complications (aOR 1.62, 95% CI 1.40 - 1.86) after leadless pacemaker implantation. CONCLUSIONS: Approximately one-third of patients undergoing leadless pacemaker implantation had CKD or ESRD. CKD and ESRD were associated with greater length and cost of stay, and inpatient mortality.

4.
Heart Rhythm ; 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38574791

RESUMO

BACKGROUND: One common mode of lead failure is insulation breach which may result in myopotential noise and device malfunction. "Pseudo-unipolarization" of bipolar pacing stimuli, as observed from a routine 12-lead ECG due to stimulus current leak has been observed with insulation breaches. OBJECTIVE: We sought to characterize this ECG finding to detect lead this type of lead malfunction. METHODS: 138 transvenous leads were analyzed, including 88 with known malfunction and 50 normal leads. The amplitude of a bipolar pacing stimulus on ECG was recorded and compared to a control dataset of newly implanted leads with bipolar stimuli normalized for output. RESULTS: The malfunction group consisted of 61% RA and 39% RV leads with mean pacing output 2.74V at 0.5ms. There was a significant difference in ECG bipolar stimulus amplitudes at time of identification of failure (7.89 ± 7.56mm per V, p<0.001) compared to those of normal leads (0.86 ± 0.41mm per V). ROC curve for the prediction of lead malfunction based on absolute EKG amplitude displayed an area under curve of 0.93 (95% CI 0.891- 0.969). When normalized for programmed stimulus output, a cutoff of 5mm/V demonstrated a sensitivity of 91% and a specificity of 92% (AUC 0.967 95% CI 0.938-0.996). CONCLUSION: The maximum amplitude of a bipolar pacing stimulus on ECG is significantly lower in normal functioning leads compared to those with known malfunction. This simply-derived variable demonstrated good accuracy at identifying lead failure due to insulation breach.

5.
Cardiol Young ; : 1-7, 2024 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-38577782

RESUMO

BACKGROUND: Paediatric cardiac electrophysiologists are essential in CHD inpatient care, but their involvement is typically limited to consultation with individual patients. In our integrated heart centre, an electrophysiologist reviews all cardiac inpatient telemetry over the preceding 24 hours and participates in daily multidisciplinary morning report. This study investigates the impact of the strategy of consistent, formalised electrophysiologist presence at multidisciplinary morning report. METHODS: This is a single-centre, prospective, observational study of electrophysiologist participation in patient encounters during heart centre multidisciplinary morning report from 10/20/2021 to 10/31/2022. Multidisciplinary morning report includes discussion of all intensive care and non-intensive care cardiac patients. An encounter was defined as reporting on one patient for one day. Electrophysiologists were initially blinded to observations. RESULTS: Two electrophysiologists were observed over 215 days encompassing 6413 patient encounters. Electrophysiologists made comments on 581(9.1%) encounters in 234 unique patients with diverse diagnoses, equating to a median of 3[interquartile range:1-4] encounters per day. These included identifications of arrhythmias and describing electrocardiographic findings. Recommendation to change management occurred in 282(48.5%) encounters, most commonly regarding medications (n = 142, 24.4%) or pacemaker management (n = 48, 8.3%). Of the 581 encounters, there were 61(10.5%) in which they corrected another physician's interpretation of rhythm or electrocardiogram. CONCLUSION: Routine electrophysiologist involvement in multidisciplinary morning report provides significant, frequent, and timely input in patient management by identifying precise rhythm-related diagnoses and allowing nuanced, patient-specific medication and pacemaker management of all cardiac patients, not just those consulted. Electrophysiologist presence at multidisciplinary morning report is a vital resource and this practice should be considered at integrated paediatric cardiac centres.

6.
Artigo em Inglês | MEDLINE | ID: mdl-38594158

RESUMO

INTRODUCTION: Pacemaker (PPM) implantation is indicated for conduction abnormalities which can develop post-transcatheter aortic valve replacement (TAVR). However, whether post-TAVR PPM risk is associated with the geographical location of the hospital and socioeconomic status of the patient is not well established. Our goal was to explore geographical and socioeconomic disparities in post-TAVR PPM implantation. METHODS: A retrospective cohort analysis was conducted using the National Inpatient Sample 2016-2020 with respective ICD-10 codes for TAVR and PPM implantation. A weighted multivariate logistic regression model was used to analyze prognostic outcomes. RESULTS: The number of patients hospitalized for undergoing TAVR was 296,740, out of which 28,265 patients had PPM implantation (prevalence 9.5 %). Patients' demographics including sex, ethnicity, household income, and insurance were not associated with risk of post-TAVR PPM except age (OR 1.01, CI 1.07-12.5, p < 0.001). Compared to rural hospitals, urban non-teaching hospitals were associated with a higher risk of post-TAVR PPM (OR 2.09, 1.3-3.43, p = 0.003). Compared to New England hospitals (ME, NH, VT, MA, RI, CT), middle Atlantic hospitals (NY, NJ, PA) were associated with highest post-TAVR PPM risk (OR 1.54, CI 1.2-1.98, p < 0.001), followed by Pacific (AK, WA, OR, CA, HI), mountain (ID, MT, WY, NV, UT, CO, AZ, NM) and east north central US. CONCLUSION: Patients' demographics including sex, ethnicity, household income, and insurance were not associated with the risk of post-TAVR PPM except for age. Compared to New England hospitals, Middle Atlantic hospitals were associated with the highest post-TAVR PPM risk followed by Pacific, Mountain, and East North Central US. Prospective studies with data on TAVR wait times, expertise of the interventional staff, and post-TAVR management and discharge planning are required to further explore the observed regional distribution of TAVR outcomes.

7.
J Med Internet Res ; 26: e47616, 2024 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-38640471

RESUMO

BACKGROUND: Telemonitoring patients with cardiac implantable electronic devices (CIEDs) can improve their care management. However, the results of cost-effectiveness studies are heterogeneous. Therefore, it is still a matter of debate whether telemonitoring is worth the investment. OBJECTIVE: This systematic review aims to investigate the cost-effectiveness of telemonitoring patients with CIEDs, focusing on its key drivers, and the impact of the varying perspectives. METHODS: A systematic review was performed in PubMed, Web of Science, Embase, and EconLit. The search was completed on July 7, 2022. Studies were included if they fulfilled the following criteria: patients had a CIED, comparison with standard care, and inclusion of health economic evaluations (eg, cost-effectiveness analyses and cost-utility analyses). Only complete and peer-reviewed studies were included, and no year limits were applied. The exclusion criteria included studies with partial economic evaluations, systematic reviews or reports, and studies without standard care as a control group. Besides general study characteristics, the following outcome measures were extracted: impact on total cost or income, cost or income drivers, cost or income drivers per patient, cost or income drivers as a percentage of the total cost impact, incremental cost-effectiveness ratios, or cost-utility ratios. Quality was assessed using the Consensus Health Economic Criteria checklist. RESULTS: Overall, 15 cost-effectiveness analyses were included. All studies were performed in Western countries, mainly Europe, and had primarily a male participant population. Of the 15 studies, 3 (20%) calculated the incremental cost-effectiveness ratio, 1 (7%) the cost-utility ratio, and 11 (73%) the health and cost impact of telemonitoring. In total, 73% (11/15) of the studies indicated that telemonitoring of patients with implantable cardioverter-defibrillators (ICDs) and cardiac resynchronization therapy ICDs was cost-effective and cost-saving, both from a health care and patient perspective. Cost-effectiveness results for telemonitoring of patients with pacemakers were inconclusive. The key drivers for cost reduction from a health care perspective were hospitalizations and scheduled in-office visits. Hospitalization costs were reduced by up to US $912 per patient per year. Scheduled in-office visits included up to 61% of the total cost reduction. Key drivers for cost reduction from a patient perspective were loss of income, cost for scheduled in-office visits and transport. Finally, of the 15 studies, 8 (52%) reported improved quality of life, with statistically significance in only 1 (13%) study (P=.03). CONCLUSIONS: From a health care and patient perspective, telemonitoring of patients with an ICD or a cardiac resynchronization therapy ICD is a cost-effective and cost-saving alternative to standard care. Inconclusive results were found for patients with pacemakers. However, telemonitoring can lead to a decrease in providers' income, mainly due to a lack of reimbursement. Introducing appropriate reimbursement could make telemonitoring sustainable for providers while still being cost-effective from a health care payer perspective. TRIAL REGISTRATION: PROSPERO CRD42022322334; https://tinyurl.com/puunapdr.


Assuntos
Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Humanos , Masculino , Análise Custo-Benefício , Qualidade de Vida , Europa (Continente)
8.
Int Breastfeed J ; 19(1): 27, 2024 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-38641819

RESUMO

BACKGROUND: Lactational mastitis is a common painful and debilitating inflammation of breast tissue, generally treated conservatively or with pus puncture in case of breast abscess. However, treating mastitis in patients with implantable surgical material located in the affected breast region can be extremely challenging. We present an unusual case of lactational mastitis complicated by pacemaker pocket infection in a breastfeeding mother. CASE PRESENTATION: A 35-year-old pacemaker-dependent female developed lactational mastitis seven weeks postpartum. Initially, the condition was treated conservatively with analgesics and antibiotics. After abscess formation, pus was aspirated using fine-needle aspiration technique. Four weeks after mastitis resolution, pacemaker pocket infection developed. According to current cardiovascular implantable electronic device infection treatment guidelines a complete surgical extraction of the entire electronic system, followed by targeted antibiotic treatment and reimplantation of a new device after infection resolution, was recommended. However, after thorough discussion with the young woman and her family and after detailed review of surgery-related risks, she declined a potentially high-risk surgical procedure. Thus, only the pulse generator was explanted; pacing leads positioned in the sub-pectoral pocket; new pacemaker implanted on the contralateral side and broad-spectrum antibiotic therapy continued for six weeks. After breastfeeding cessation, and with chronic fistula development at the primary pacemaker implantation site, the possibility of delayed surgical intervention including complete extraction of retained pacemaker leads was again thoroughly discussed with her. After thoughtful consideration the woman consented to the proposed treatment strategy. A surgical procedure including transvenous lead extraction through the primary implantation venous entry site, using hand-powered bidirectional rotational sheaths, was successfully performed, removing all retained leads through the left subclavian venous entry site, and leaving the fully functional and clinically uninfected pacemaker on the contralateral site intact. CONCLUSION: Although patients' decisions for delayed extraction in a case of cardiovascular implantable electronic device infection should be discouraged by attending physicians and members of interdisciplinary teams, our case shows that a stepwise treatment strategy may be successful as a bailout clinical scenario in patients with specific requests, demands and / or clinical needs.


Assuntos
Mastite , Marca-Passo Artificial , Humanos , Feminino , Adulto , Aleitamento Materno , Abscesso/tratamento farmacológico , Mastite/terapia , Marca-Passo Artificial/efeitos adversos , Lactação , Antibacterianos/uso terapêutico
9.
Tex Heart Inst J ; 51(1)2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38564374

RESUMO

This report discusses a case of transient 2:1 atrioventricular block with conduction system pacing 4 hours after leadless right ventricular pacemaker implantation in a 19-year-old patient with a history of cardioinhibitory syncope and asystole cardiac arrest but without preexisting atrioventricular block. The atrioventricular block was resolved spontaneously. Pacing morphology was suggestive of right bundle branch pacing. Neither 2:1 atrioventricular block nor conduction system pacing has previously been a reported outcome of right ventricular leadless pacemaker implantation. The report demonstrates that conduction system pacing with leadless devices is achievable. Further study of techniques, limitations, and complications related to intentional right ventricular leadless conduction system pacing is warranted.


Assuntos
Bloqueio Atrioventricular , Marca-Passo Artificial , Humanos , Adulto Jovem , Adulto , Bloqueio Atrioventricular/diagnóstico , Bloqueio Atrioventricular/terapia , Bloqueio Atrioventricular/etiologia , Estimulação Cardíaca Artificial/métodos , Marca-Passo Artificial/efeitos adversos , Sistema de Condução Cardíaco , Ventrículos do Coração , Resultado do Tratamento
10.
J Electrocardiol ; 84: 100-102, 2024 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-38581752

RESUMO

A 69-year-old woman had three syncopal events while flying on an airplane. She was found to be profoundly bradycardic. Two 12­lead electrocardiograms (ECGs) showed ventricular rates in the thirties. In one, the QRS complexes were narrow. In the second ECG, there were wide negative deflections following the QRS complexes. Analysis of telemetry recordings revealed the underlying mechanism and helped establish appropriate programing of an implanted pacemaker.

11.
Artigo em Romano | MEDLINE | ID: mdl-38583089

RESUMO

A 16-year-old female with dual-chamber pacemaker (Medtronic Azure XT DR), due to symptomatic third-degree congenital atrioventricular (AV) block, presented to our ambulatory with dizziness and presyncopal episodes preceded by prodromes, occurring over the last few months. The device was programmed in DDD mode with an upper rate of 150 bpm. A head-up Tilt Test (HUTT) revealed the unexpected emergence of 2:1 electronic AV block at a sinus rate of 130 bpm.

12.
J Cardiothorac Surg ; 19(1): 181, 2024 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-38580985

RESUMO

BACKGROUND: A frequent complication of Fontan operations is unilateral diaphragmatic paresis, which leads to hemodynamic deterioration of the Fontan circulation. A potential new therapeutic option is the unilateral diaphragmatic pacemaker. In this study, we investigated the most effective stimulation location for a potential fully implantable system in a porcine model. METHODS: Five pigs (20.8 ± 0.95 kg) underwent implantation of a customized cuff electrode placed around the right phrenic nerve. A bipolar myocardial pacing electrode was sutured adjacent to the motor point and peripherally at the costophrenic angle (peripheral diaphragmatic muscle). The electrodes were stimulated 30 times per minute with a pulse duration of 200 µs and a stimulation time of 300 ms. Current intensity was the only variable changed during the experiment. RESULTS: Effective stimulation occurred at 0.26 ± 0.024 mA at the phrenic nerve and 7 ± 1.22 mA at the motor point, a significant difference in amperage (p = 0.005). Even with a maximum stimulation of 10 mA at the peripheral diaphragm muscle, however, no effective stimulation was observed. CONCLUSION: The phrenic nerve seems to be the best location for direct stimulation by a unilateral thoracic diaphragm pacemaker in terms of the required amperage level in a porcine model.


Assuntos
Nervo Frênico , Paralisia Respiratória , Humanos , Criança , Suínos , Animais , Diafragma , Paralisia Respiratória/etiologia , Paralisia Respiratória/terapia , Eletrodos , Próteses e Implantes , Estimulação Elétrica
13.
J Clin Med ; 13(7)2024 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-38610667

RESUMO

Background: Cardiac resynchronization therapy (CRT) has evolved into an established therapy for patients with chronic heart failure and a wide QRS complex. Data on long-term outcomes over time are scarce and the criteria for implantation remain a subject of investigation. Methods: An international, multicenter, retrospective registry includes 2275 patients who received CRT between 30 November 2000 and 31 December 2019, with a mean follow-up of 3.6 ± 2.7 years. Four time periods were defined, based on landmark trials and guidelines. The combined endpoint was a composite of all-cause mortality, heart transplantation, or left ventricular assist device implantation. Results: The composite endpoint occurred in 656 patients (29.2%). The mean annual implantation rate tripled from 31.5 ± 17.4/year in the first period to 107.4 ± 62.4/year in the last period. In the adjusted Cox regression analysis, the hazard ratio for the composite endpoint was not statistically different between time periods. When compared to sinus rhythm with left bundle branch block (LBBB), a non-LBBB conduction pattern (sinus rhythm: HR 1.51, 95% CI 1.12-2.03; atrial fibrillation: HR 2.08, 95% CI 1.30-3.33) and a QRS duration below 130 ms (HR 1.64, 95% CI 1.29-2.09) were associated with a higher hazard ratio. Conclusions: Despite innovations, an adjusted regression analysis revealed stable overall survival over time, which can at least partially be explained by a shift in patient characteristics.

14.
Neth Heart J ; 2024 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-38653922

RESUMO

BACKGROUND: During transcatheter aortic valve implantation (TAVI), secondary access is required for angiographic guidance and temporary pacing. The most commonly used secondary access sites are the femoral artery (angiographic guidance) and the femoral vein (temporary pacing). An upper extremity approach using the radial artery and an upper arm vein instead of the lower extremity approach using the femoral artery and femoral vein may reduce clinically relevant secondary access site-related bleeding complications, but robust evidence is lacking. TRIAL DESIGN: The TAVI XS trial is a multicentre, randomised, open-label clinical trial with blinded evaluation of endpoints. A total of 238 patients undergoing transfemoral TAVI will be included. The primary endpoint is the incidence of clinically relevant bleeding (i.e. Bleeding Academic Research Consortium (BARC) type 2, 3 or 5 bleeding) of the randomised secondary access site (either diagnostic or pacemaker access, or both) within 30 days after TAVI. Secondary endpoints include time to mobilisation after TAVI, duration of hospitalisation, any BARC type 2, 3 or 5 bleeding, and early safety at 30 days according to Valve Academic Research Consortium­3 criteria. CONCLUSION: The TAVI XS trial is the first randomised trial comparing an upper extremity approach to a lower extremity approach with regard to clinically relevant secondary access site-related bleeding complications. The results of this trial will provide important insights into the safety and efficacy of an upper extremity approach in patients undergoing transfemoral TAVI.

16.
JMIR Res Protoc ; 13: e47525, 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38588529

RESUMO

BACKGROUND: In Tunisia, the number of cardiac implantable electronic devices (CIEDs) is increasing, owing to the increase in patient life expectancy and expanding indications. Despite their life-saving potential and a significant reduction in population morbidity and mortality, their increased numbers have been associated with the development of multiple early and late complications related to vascular access, pockets, leads, or patient characteristics. OBJECTIVE: The study aims to identify the rate, type, and predictors of complications occurring within the first year after CIED implantation. It also aims to describe the demographic and epidemiological characteristics of a nationwide sample of patients with CIED in Tunisia. Additionally, the study will evaluate the extent to which Tunisian electrophysiologists follow international guidelines for cardiac pacing and sudden cardiac death prevention. METHODS: The Tunisian National Study of Cardiac Implantable Electronic Devices (NATURE-CIED) is a national, multicenter, prospectively monitored study that includes consecutive patients who underwent primary CIED implantation, generator replacement, and upgrade procedure. Patients were enrolled between January 18, 2021, and February 18, 2022, at all Tunisian public and private CIED implantation centers that agreed to participate in the study. All enrolled patients entered a 1-year follow-up period, with 4 consecutive visits at 1, 3, 6, and 12 months after CIED implantation. The collected data are recorded electronically on the clinical suite platform (DACIMA Clinical Suite). RESULTS: The study started on January 18, 2021, and concluded on February 18, 2023. In total, 27 cardiologists actively participated in data collection. Over this period, 1500 patients were enrolled in the study consecutively. The mean age of the patients was 70.1 (SD 15.2) years, with a sex ratio of 1:15. Nine hundred (60%) patients were from the public sector, while 600 (40%) patients were from the private sector. A total of 1298 (86.3%) patients received a conventional pacemaker and 75 (5%) patients received a biventricular pacemaker (CRT-P). Implantable cardioverter defibrillators were implanted in 127 (8.5%) patients. Of these patients, 45 (3%) underwent CRT-D implantation. CONCLUSIONS: This study will establish the most extensive contemporary longitudinal cohort of patients undergoing CIED implantation in Tunisia, presenting a significant opportunity for real-world clinical epidemiology. It will address a crucial gap in the management of patients during the perioperative phase and follow-up, enabling the identification of individuals at particularly high risk of complications for optimal care. TRIAL REGISTRATION: ClinicalTrials.gov NCT05361759; https://classic.clinicaltrials.gov/ct2/show/NCT05361759. INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID): RR1-10.2196/47525.

17.
J Am Heart Assoc ; : e032777, 2024 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-38639357

RESUMO

BACKGROUND: A delayed and recurrent complete atrioventricular block (CAVB) is a life-threatening complication of transcatheter aortic valve replacement (TAVR). Post-TAVR evaluation may be important in predicting delayed and recurrent CAVB requiring permanent pacemaker implantation (PPI). The impact of new-onset right bundle-branch block (RBBB) after TAVR on PPI remains unknown. METHODS AND RESULTS: In total, 407 patients with aortic stenosis who underwent TAVR were included in this analysis. Intraprocedural CAVB was defined as CAVB that occurred during TAVR. A 12-lead ECG was evaluated at baseline, immediately after TAVR, on postoperative days 1 and 5, and according to the need to identify new-onset bundle-branch block (BBB) and CAVB after TAVR. Forty patients (9.8%) required PPI, 17 patients (4.2%) had persistent intraprocedural CAVB, and 23 (5.7%) had delayed or recurrent CAVB after TAVR. The rates of no new-onset BBB, new-onset left BBB, and new-onset RBBB were 65.1%, 26.8%, and 4.7%, respectively. Compared with patients without new-onset BBB and those with new-onset left BBB, the rate of PPI was higher in patients with new-onset RBBB (3.4% versus 5.6% versus 44.4%, P<0.0001). On post-TAVR evaluation in patients without persistent intraprocedural CAVB, the multivariate logistic regression analysis showed that new-onset RBBB was a statistically significant predictor of PPI compared with no new-onset BBB (odds ratio [OR], 18.0 [95% CI, 5.94-54.4]) in addition to the use of a self-expanding valve (OR, 2.97 [95% CI, 1.09-8.10]). CONCLUSIONS: Patients with new-onset RBBB after TAVR are at high risk for PPI.

18.
Heart Rhythm O2 ; 5(3): 158-167, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38560372

RESUMO

Background: Cardiac implantable electronic devices (CIEDs), such as permanent pacemakers, implantable cardioverter-defibrillators, and cardiac resynchronization therapy devices, alleviate morbidity and mortality in various diseases. There is a paucity of real-world data on CIED complications and trends. Objectives: We sought to describe trends in noninfectious CIED complications over the past 3 decades in Olmsted County. Methods: The Rochester Epidemiology Project is a medical records linkage system comprising records of over 500,000 residents of Olmsted County from 1966 to present. CIED implantations between 1988 and 2018 were determined. Trends in noninfectious complications within 30 days of implantation were analyzed. Results: A total of 157 (6.2%) of 2536 patients who received CIED experienced device complications. A total of 2.7% of the implants had major complications requiring intervention. Lead dislodgement was the most common (2.8%), followed by hematoma (1.7%). Complications went up from 1988 to 2005, and then showed a downtrend until 2018, driven by a decline in hematomas in the last decade (P < .01). Those with complications were more likely to have prosthetic valves. Obesity appeared to have a protective effect in a multivariate regression model. The mean Charlson comorbidity index has trended up over the 30 years. Conclusion: Our study describes a real-world trend of CIED complications over 3 decades. Lead dislodgements and hematomas were the most common complications. Complications have declined over the last decade due to safer practices and a better understanding of anticoagulant management.

20.
Int J Mol Sci ; 25(7)2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38612808

RESUMO

We examined the localization of the 5-hydroxytryptamine (5-HT) receptor and its effects on mouse colonic interstitial cells of Cajal (ICCs) using electrophysiological techniques. Treatment with 5-HT increased the pacemaker activity in colonic ICCs with depolarization of membrane potentials in a dose-dependent manner. Hyperpolarization-activated cyclic nucleotide-gated (HCN) channel blockers blocked pacemaker activity and 5-HT-induced effects. Moreover, an adenylate cyclase inhibitor inhibited 5-HT-induced effects, and cell-permeable 8-bromo-cAMP increased the pacemaker activity. Various agonists of the 5-HT receptor subtype were working in colonic ICCs, including the 5-HT4 receptor. In small intestinal ICCs, 5-HT depolarized the membrane potentials transiently. Adenylate cyclase inhibitors or HCN blockers did not show any influence on 5-HT-induced effects. Anoctamin-1 (ANO1) or T-type Ca2+ channel blockers inhibited the pacemaker activity of colonic ICCs and blocked 5-HT-induced effects. A tyrosine protein kinase inhibitor inhibited pacemaker activity in colonic ICCs under controlled conditions but did not show any influence on 5-HT-induced effects. Among mitogen-activated protein kinase (MAPK) inhibitors, a p38 MAPK inhibitor inhibited 5-HT-induced effects on colonic ICCs. Thus, 5-HT's effect on pacemaker activity in small intestinal and colonic ICCs has excitatory but variable patterns. ANO1, T-type Ca2+, and HCN channels are involved in 5-HT-induced effects, and MAPKs are involved in 5-HT effects in colonic ICCs.


Assuntos
Doenças do Colo , Células Intersticiais de Cajal , Animais , Camundongos , Masculino , Serotonina/farmacologia , Células Intersticiais do Testículo , Inibidores de Adenilil Ciclases , Bloqueadores dos Canais de Cálcio , Inibidores de Proteínas Quinases
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...